[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Alternator Belt service
- Subject: Re: Alternator Belt service
- From: Mick <bmwmick@xxxxxxxxxxx>
- Date: Sun, 30 Jul 2006 19:29:50 -0700
>>NJ
>
>
>Paul,
> The PolyV belt does get re tensioned once at 6,000 miles and replaced at
>36,000
>The previous pulley SI Bulletin (#2747) I mentioned, replaced the pulleys
>and installed a new belt. The Upper pulley was changed from
>Aluminum to Steel. All Oilheads AFTER 09/1994 had this change
>installed at production. It was NOT a Service Action item and was
>Service Information only.
>
>Mick
>Tucson
I misread that bulletin I guess. The ELAST never needs re tensioning
but the PolyV belt does.....at 6,000 miles, one time.
Mick
Tucson
------------------------------